Product Info & Order Tracking
0800 622 6226


 [ Home ]  [ Login 
 [  Items: Value:  ]
 

Product Categories

Online Catalogue |  ECG |  Resting ECG's and Software |  Welch Allyn CP1-2E4 CP100 12 Channel ECG


Welch Allyn CP1-2E4 CP100 12 Channel ECG
Welch Allyn CP1-2E4 CP100 12 Channel ECG

Welch Allyn CP 100 Electrocardiograph

A reliable, easy-to-use, and cost-effective ECG device for almost any office setting.

A 12-lead resting ECG that provides accurate measurements
Optional MEANS ECG interpretation software for a second opinion
High-resolution thermal printer generates full-sized standard and customized reports
Lead quality graphic saves valuable time by highlighting poor connections
Full alphanumeric keyboard and LCD screen for easy patient data entry

Free Welch Allyn Diagnostic Set - when purchasing this item

*** Free ECG Training Course if You buy a Welch Allyn CP100 or CP200 ECG Machine ***



Welch Allyn CP 100 Electrocardiograph: Specifications
Dimensions: 15.6 in (39.7 cm) X 6.2 in (15.7 cm) X 16.2 in (41.1 cm)

Weight: 11.6 lb (5.3 kg)

Keyboard type: Elastomer keypad with complete alphanumeric keys

Paper type: 8.25 x 11 inches (21 x 28 cm), Z-fold thermal paper, 200 sheets

Thermal printer (internal): Computer-controlled dot array, 8 dots/mm

Thermal paper speeds 10, 25, 50 mm/s

Gain settings:
Auto ECGs: 5, 10, 20 mm/mV, AUTO
Rhythm ECGs: 5, 10, 20 mm/mV

Report print formats:
Auto ECGs: 3x4, 3x4+ 1R, 3x4 +3R, 6x2, 12x1, 6x2 50 mm/s, 6x2 Ext.
Rhythm ECGs: 3 leads at a time
Average cycles: 3x4 50 mm/s + 3R, 6x2 50 mm/s + 6R

Frequency range: 0.3 to 150 Hz

Digital sampling rate: > 1,000 samples/second/channel

Pacemaker detection: ANSI/AAMI EC11

Power requirement: Universal AC power supply 100-240 V , 50/60 Hz , 2.2 A maximum

Fuses
AC: Time-delay type, 2 amp 250 V rating, Littlefuse 0215002 or equivalent.
DC (battery fuse): Fast-acting type, 10 amp 32 V rating, Bussman ATC-10 or equivalent.

Lead configurations: Standard, Cabrera

Rechargeable battery: Lead acid gel, 6 volt, 5 AH
Prints up to 100 continuous ECGs per charge
12-hour recharging

Filters: 0.5 Hz high-performance baseline filter
35 Hz muscle-tremor filter
AC-interference filter 50 Hz or 60 Hz

Safety, EMC, and regulatory compliance:
ANSI/AAMI EC11* UL60601-1
CAN/CSA C22.2 No. 601.1 IEC/EN 60601-1
CAN/CSA C22.2 No. 601.1.1 IEC/EN 60601-1-1
CAN/CSA C22.2 No. 601.1.2 IEC/EN 60601-1-2
CAN/CSA C22.2 No. 601.1.4 IEC/EN 60601-1-4
CAN/CSA C22.2 No. 601.2.25 IEC/EN 60601-2-25

Standard connectivity: SD memory card slot (for use with cards 64 MB)

Connectivity with electronic medical records: Supported through the Welch Allyn CardioPerfect workstation software

Electrodes: Rigorously tested for conductivity, adhesion, and hypoallergenic qualities, and exceed all AAMI standards

Cables and wires: Meet or exceed IEC 60601
Environmental operating conditions:
Temperature: +10 C to +40 C (+50 F to +104 F)
Relative humidity: 15 - 95% noncondensing
Altitude: 700 - 1060 hPa

Environmental storage conditions:
Temperature: -20 C to +49 C (-4 F to +120 F)
Relative humidity: 15 - 95% noncondensing (30 - 70% for printing)
Altitude: 500 - 1060 hPa

Protection against electric shock: Class I, internally powered
Type CF

Protection against ingress of water, per IEC 60529: IPX0

Mode of operation: Continuous

* Per AAMI EC11:1991/(R)2001 Diagnostic Electrocardiographic Devices, Section 3.1.2.1 Disclosure of cautionary information/ performance characteristics paragraph c) Accuracy of input signal reproduction, the manufacturer shall disclose the methods used to establish overall system error and frequency response. Welch Allyn has used methods A and D, as prescribed in section 3.2.7.2 and 4.2.7.2 of this same standard, to verify overall system error and frequency response. Because of the sampling characteristics and the asynchronism between sample rate and signal rate, digital ECG systems such as the CP 100 and CP 200 may produce a noticeable modulating effect from one cycle to the next, particularly in pediatric recordings. This phenomenon is not physiologic.



Code: CP1-2E4













Online Catalogue |  ECG |  Resting ECG's and Software |  Welch Allyn CP1-2E4 CP100 12 Channel ECG